Double Sided LED Emergency Exit Sign Combo: The Complete Commercial Buyer’s Guide

by Ayesha Fatima 29 Sep 2025

Introduction: Why Exit Signs Are a Critical Part of Safety

Every commercial building, whether it’s a warehouse, office tower, hospital, or retail store, is required to have illuminated emergency exit signage. These aren’t just legal requirements—they’re life-saving devices designed to keep people safe in the event of fire, power outages, or other emergencies.

The Double Sided LED Emergency EXIT Sign Combo is one of the most practical solutions available today. It combines a clear double-sided exit sign with dual LED emergency lights, a reliable backup battery, and a fire-resistant housing. For contractors, facility managers, and building owners, this all-in-one fixture reduces installation costs, simplifies compliance, and provides peace of mind that the building will remain safe during emergencies.

In this guide, we’ll cover everything you need to know before buying, installing, and maintaining this sign, including technical features, compliance standards, installation steps, real-world applications, and maintenance tips. By the end, you’ll know exactly why this model is one of the most trusted choices in commercial safety lighting.

The Role of Exit Signs in Commercial Buildings

Exit signs are more than glowing letters—they are life safety systems. In a dark or smoke-filled environment, panic can spread quickly. Clear, illuminated signage helps maintain order and guides occupants to safety.

Organizations such as OSHA (Occupational Safety and Health Administration) and NFPA (National Fire Protection Association) mandate that all commercial and public buildings have reliable emergency signage that:

  • Is illuminated at all times.

  • Has a backup power source lasting at least 90 minutes.

  • Uses letters large enough to be visible from a distance.

Failure to comply doesn’t just risk inspection fines; it creates liability and, more importantly, puts lives at risk.

Key Features of the Double Sided LED Emergency Exit Sign Combo

The Double Sided LED Exit Sign Combo is built specifically for commercial environments. Its design reduces installation costs by combining multiple features into a single unit.

Dual Functionality

The fixture combines an exit sign and emergency lighting in one housing. This means fewer units to install, lower costs, and reduced wiring.

Double-Sided Visibility

Unlike single-sided models, this sign provides visibility from both directions, making it ideal for hallways, stairwells, and intersections.

High-Output LED Illumination

Red LED lettering ensures the sign is visible even in low-light or smoky conditions. The dual LED lamp heads are fully adjustable to direct light toward exits or pathways.

Battery Backup

A rechargeable NiCad battery provides a minimum of 90 minutes of power in the event of an outage. This ensures compliance with NFPA 101 standards.

Fire-Resistant Housing

Made from UL 94V-0 thermoplastic, the housing is flame retardant, durable, and lightweight.

Universal Power Supply

The unit operates on 120–277V AC, making it compatible with virtually all U.S. electrical systems.

Certifications

The sign is ETL Listed and UL compliant, ensuring it meets inspection requirements.

Compliance and Regulations

Commercial buyers are primarily concerned with compliance, since failure to meet code can result in costly re-inspections or liability issues.

  • OSHA 1910.37 requires illuminated exit routes with signs that remain lit during power failures.

  • NFPA 101 (Life Safety Code) mandates 90 minutes of emergency illumination.

  • IBC (International Building Code) specifies minimum visibility and placement.

The Double Sided LED Emergency Exit Sign Combo meets these requirements out of the box, eliminating compliance concerns.

Buying Considerations for Contractors and Facility Managers

Before selecting an exit sign, there are several factors to evaluate:

Lettering Color

Most states require red letters, which this model provides. Some jurisdictions, however, mandate green lettering. Always verify local requirements.

Mounting Style

This fixture supports wall, ceiling, and end mounting, making it flexible for different building layouts.

Battery Requirements

The built-in NiCad battery provides 90 minutes of backup, meeting national standards.

Durability

The fire-resistant housing is critical in industrial or high-traffic environments where impact resistance is important.

Maintenance

LED models reduce long-term maintenance costs, with lifespans up to 50,000 hours.

Installation Guide

Installation is straightforward but must be completed correctly to ensure compliance.

  1. Preparation

    • Turn off power at the breaker.

    • Unpack and verify that all components are included.

  2. Mounting

    • Choose between wall, ceiling, or end mounting.

    • Secure the mounting bracket to the junction box.

  3. Wiring

    • Connect the live and neutral wires (works with both 120V and 277V).

    • Attach the ground wire.

    • Connect the battery pack.

  4. Assembly

    • Snap the housing onto the bracket.

    • Install faceplates and directional arrows as required.

  5. Testing

    • Restore power.

    • Press the test button to confirm functionality.

    • Allow the battery to charge for 24 hours before official use.

Most contractors report that this unit can be installed in less than 30 minutes.

Maintenance and Testing Requirements

Routine testing ensures the unit will perform when needed.

  • Monthly Test: Press the test button to verify both the sign and lights work.

  • Annual Test: Simulate a 90-minute power outage to confirm battery reliability.

  • Battery Replacement: Typically every 3–5 years.

Failure to perform routine tests can result in inspection failures, so facility managers should integrate this into their safety protocols.

Real-World Applications

Warehouses

Large open spaces benefit from the dual floodlights, which provide illumination across wide aisles.

Office Buildings

The professional design blends with modern interiors while ensuring compliance.

Hospitals and Schools

High-traffic facilities rely on dependable exit signage to manage safe evacuations.

Retail Stores and Restaurants

Compact design ensures it doesn’t detract from customer-facing aesthetics.

Common Issues and Troubleshooting

  • Sign not illuminated: Check wiring and battery connection.

  • Battery not charging: Replace NiCad pack.

  • Dim lights: Verify voltage supply and battery performance.

FAQs

How long does the battery last in an outage?
A minimum of 90 minutes, per NFPA standards.

Can the emergency lights be adjusted?
Yes, both lamp heads rotate for directional lighting.

Is the housing fire resistant?
Yes, UL 94V-0 rated thermoplastic.

Can this be installed outdoors?
No, this unit is for indoor use only.

What’s the lifespan of the LEDs?
Approximately 50,000 hours.

Is this fixture ETL listed?
Yes, fully ETL and UL compliant.

Why Buy from SwitchToLED

SwitchToLED specializes in commercial-grade lighting solutions with a focus on bulk and contractor supply. Benefits include:

  • Automatic volume discounts at checkout.

  • Free shipping on orders over $99.

  • U.S. stock and fast delivery.

  • Dedicated support for contractors and facility managers.

Conclusion

The Double Sided LED Emergency EXIT Sign Combo is a reliable, code-compliant, and cost-effective solution for any commercial facility. With dual functionality, long-lasting LED illumination, and a backup battery that meets NFPA standards, it simplifies compliance while enhancing safety.

Whether you’re an electrician outfitting a new building or a facility manager replacing outdated signs, this model delivers everything required for inspections and real-world emergencies.